Allow negative peak temperatures for PhaseChangeHysteresis NewFeatureRequest This "issue" is a new feature request, not a defect report
#10472 opened Apr 18, 2024 by shorowit
3 tasks
ZoneAirMassFlowConservation causes no change in zone sizing when Lights: Return Air Fraction is changed Defect Includes code to repair a defect in EnergyPlus
#10468 opened Apr 15, 2024 by rraustad
3 tasks
Zone Equipment array is not always initialized (causes exception/crash) Defect Includes code to repair a defect in EnergyPlus
#10459 opened Apr 2, 2024 by tanaya-mankad
Plant low flow rate tolerance prevents minimum pump flow rate to be enforced Defect Includes code to repair a defect in EnergyPlus
#10456 opened Mar 29, 2024 by lymereJ
1 of 3 tasks
Suggestion regarding EnergyPlus HTML results
#10451 opened Mar 27, 2024 by Mouse-Diplodicus
3 tasks
WaterUse:Connections node volume flow rate does not match WaterUse:Equipment volume flow rate Defect Includes code to repair a defect in EnergyPlus
#10443 opened Mar 20, 2024 by rraustad
1 of 3 tasks
Problems building with 3.12 on GHA Defect Includes code to repair a defect in EnergyPlus
#10439 opened Mar 14, 2024 by jmarrec
3 tasks
Inconsistent maximum flow rate for fans and terminals when sizing on ventilation needs Defect Includes code to repair a defect in EnergyPlus
#10438 opened Mar 14, 2024 by lymereJ
2 tasks
VRF heating issue: same heating power with different compressor speed at low heating load Defect Includes code to repair a defect in EnergyPlus
#10427 opened Mar 6, 2024 by yujiex
1 of 3 tasks
Phase Change Hysteresis Object is Faulty
#10420 opened Mar 2, 2024 by ArefAboud
2 tasks
Non-coincident system sizing option reports the coincident peak time if one exists Defect Includes code to repair a defect in EnergyPlus
#10402 opened Feb 19, 2024 by rraustad
3 tasks
Long elapsed times are not recorded correctly Defect Includes code to repair a defect in EnergyPlus
#10399 opened Feb 15, 2024 by keigo-nomura
3 tasks
Support Inch-Pound unit conversions for OutputControl:Files CSV files NewFeatureRequest This "issue" is a new feature request, not a defect report
#10397 opened Feb 12, 2024 by JasonGlazer
VRF Cooling issue: Heat Pump outdoor unit fan power does not consider runtime fraction Defect Includes code to repair a defect in EnergyPlus
#10390 opened Feb 2, 2024 by yujiex
1 of 3 tasks
The PlantLoop:EIR heat pump power calculation is incorrect Defect Includes code to repair a defect in EnergyPlus
#10387 opened Jan 31, 2024 by rraustad
3 tasks
EnergyPlus Stuck with Unhandeled Exception Defect Includes code to repair a defect in EnergyPlus
#10386 opened Jan 30, 2024 by TiejunWu
1 of 3 tasks
EnergyPlus 24.1
New Mac Warnings
#10378 opened Jan 26, 2024 by Myoldmopar
Inconsistency in Phi, Theta calculations for Screens SeverityLow This defect is low severity, generally indicating low impact with a workaround available UnconfirmedDefect Defect has not yet confirmed to be an actual issue
#10373 opened Jan 21, 2024 by amirroth